KrzyszurandClaude Opus 5.5 bb933ff748 Serial monitor redesign: Test box button, InfluxDB row in the checklist
- Test box: restart + start-up capture + online InfluxDB check (data newer
  than the restart), with a status strip; checklist and findings are the
  main view, live log / guided troubleshooting / box details are tabs,
  rarely used actions in a More menu
- light palette on all systems (macOS dark mode made the colours unreadable)
- new rule influx.invalid_value: -inf from a silent microphone makes
  InfluxDB reject every upload (HTTP 400); guide end names it
- exclusive serial port on macOS/Linux: two tool windows no longer split
  the log between them
- InfluxDB check: `since` filter, neutral wording when nothing new arrives

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-01 00:06:48 +02:00

3.4 KiB

Technician tool v0.10 - changes (draft)

  • New tab Wi-Fi (USB): write the Wi-Fi name and password to the box's SD card over the USB cable, without opening the case (firmware usb_console, kota wifi set). Shows each step: command support check, stored, restart in Wi-Fi mode, connected with signal strength (polls kota health). Also reads the stored network (kota wifi get, password never shown) and removes it (kota wifi clear, back to Matter).
  • The password is sent hex-encoded, never written to the session log or the service report.
  • Diagnosis: restarts usb_wifi_set / usb_wifi_clear are intentional (no "unexpected restart"); box self-report shows the stored Wi-Fi network; cmd health replies update the health line.
  • firmware/: merged-binary-v13.bin (usb_console, build 3ae273ec) replaces merged-binary.bin (build 4f10989e, still in git tag v0.9). Note: v13 reports the same version 1.0.16 and compile date as the previous build; the firmware team should bump the version for the next build.
  • error_ids.csv updated from the firmware (E-CON-01).
  • Test that builds the main window (catches start-up errors).
  • New check Sensor data in the database (InfluxDB) (Guided troubleshooting; also the last step of the Quick check on the green path): queries InfluxDB online (read-only) for the box's newest points and tells apart "sensor data arrives", "status arrives but sensor data does not", "offline now" and "never seen". Polls every 30 s for up to 4 minutes. With a stopped RTC in the log it concludes that the sensor readings are lost (they are stamped 1 Jan 2000) - found on box A4:CB:8F:C9:47:3C, which reported only device_status and microphone. The result and the per-measurement times go into the report and the service note.
  • Settings > InfluxDB access...: address, organisation, bucket and a read token (or the KOTA_INFLUX_TOKEN environment variable). Defaults: influx.kota-app.com, org kota, bucket sensorbox. The token is never written to the session log or the service report.
  • macOS: Connect no longer restarts the box (pyserial dropped DTR before RTS, passing through the USB-Serial-JTAG reset state). Windows unchanged.
  • Serial monitor redesigned. One green Test box button: restarts the box, records the start-up and then checks InfluxDB online (data must be newer than the restart), about 4 minutes. A status strip shows what the test is doing and its result. The test checklist (start-up steps + the new row "Sensor data in InfluxDB (online check)") and the findings are the main view; the live log, guided troubleshooting and box details (LED, firmware, self-report) are tabs on the right. Rarely used actions moved to More.
  • Light colour scheme on every system: with macOS dark mode the status colours were unreadable. Larger log font on macOS.
  • New finding Box sends an invalid value (-inf/nan) - InfluxDB rejects all its data: a silent microphone makes the firmware upload dbfs=-inf,db=-inf; InfluxDB then refuses the whole upload (HTTP 400), so neither the status nor the sensor data arrive (box A4:CB:8F:C9:47:3C). The InfluxDB check names it as the cause.
  • The serial port is opened exclusively on macOS/Linux: a second tool window no longer steals half of the log lines; it reports that the port is in use.
  • Start-up step "Data uploaded to InfluxDB" renamed "Upload accepted by InfluxDB (box log)" - it comes from the box's own log, the online row checks the database.