11 Commits
Author SHA1 Message Date
KrzyszurandClaude Opus 5.5 bb933ff748 Serial monitor redesign: Test box button, InfluxDB row in the checklist
- Test box: restart + start-up capture + online InfluxDB check (data newer
  than the restart), with a status strip; checklist and findings are the
  main view, live log / guided troubleshooting / box details are tabs,
  rarely used actions in a More menu
- light palette on all systems (macOS dark mode made the colours unreadable)
- new rule influx.invalid_value: -inf from a silent microphone makes
  InfluxDB reject every upload (HTTP 400); guide end names it
- exclusive serial port on macOS/Linux: two tool windows no longer split
  the log between them
- InfluxDB check: `since` filter, neutral wording when nothing new arrives

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-01 00:06:48 +02:00
KrzyszurandClaude Opus 5.5 66cb804102 Checklist: verify that sensor data reaches InfluxDB
New guided check "Sensor data in the database (InfluxDB)", also the last
step of the Quick check on the green path. It queries InfluxDB (read
token) for the newest point per measurement of the box and tells apart:
sensor data arrives / status arrives without sensor data / offline now /
never seen / check not possible. Polls every 30 s for up to 4 minutes.
With a stopped RTC in the log it concludes that sensor readings are lost
(stamped 1 Jan 2000): box A4:CB:8F:C9:47:3C sent only device_status and
microphone.

- service/influx.py: query, CSV parsing, classification (no new deps)
- guides: new step type "influx" (host answers via influx_result)
- Settings > InfluxDB access (or KOTA_INFLUX_TOKEN); token never logged
- service status mapping for tech.influx.* findings

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-01 00:06:48 +02:00
kkallasandClaude Opus 5.5 c41fa101b6 Technician guide as PDF (docs/INSTRUKCJA_TECHNIKA.pdf)
Printable A4 version of the guide with the screenshots, linked from the README.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-30 15:45:51 +02:00
kkallasandClaude Opus 5.5 e299ef40f0 USB wording: a USB 2.0 type-A plug on the way; hubs are fine
Guide, README, quick start and flashing hints no longer say 'no hub' or 'directly to the laptop'; the requirement is a USB 2.0 type-A plug between box and computer (USB-C only is the failing case).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-30 15:41:12 +02:00
kkallasandClaude Opus 5.5 39f0d1718c Technician guide with screenshots; USB 2.0 type-A cable requirement
docs/INSTRUKCJA_TECHNIKA.md: install, update, connecting the box, reading
the Diagnosis panel, guided checks, Wi-Fi over USB, flashing, SD card,
service report, LED table and common problems, with screenshots of the
app rendered from a real v13 capture (docs/img). The box must be
connected with a USB 2.0 type-A cable directly to the computer; the
quick-start screen and README say so too.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-30 15:39:02 +02:00
kkallasandClaude Opus 5.5 ab420220e1 Wi-Fi over USB tab for firmware with the USB console (v13)
Writes / reads / removes the box's Wi-Fi over the serial port with the
usb_console commands (kota ping, wifi set|get|clear, health) and follows
the box through the restart until it joins the network. The password is
sent hex-encoded and never logged.

firmware/ now holds merged-binary-v13.bin (build 3ae273ec) instead of the
previous 1.0.16 build; error_ids.csv synced with the firmware.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-29 17:30:35 +02:00
kkallasandClaude Opus 5.5 bfbbd537d5 Updater messages without "!", README and changelog for v0.9
cmd drops "!" from messages when delayed expansion is on, so errors
read "ERROR:". README describes the two files per system and the
first install from a release zip.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-28 19:43:50 +02:00
kkallas bfa7edce6f Technician tool v0.8
Imported from the Google Drive folder 004-technician_tool/v0.8.
2026-09-28 19:19:55 +02:00
kkallas dd915b5a74 Technician tool v0.7
Imported from the Google Drive folder 004-technician_tool/v0.7.
2026-09-28 19:11:20 +02:00
kkallas f5b32e1554 Technician tool v0.5
Imported from the Google Drive folder 004-technician_tool/v0.5.
2026-09-26 18:30:51 +02:00
kkallas e161941672 Technician tool v0.3
Imported from the Google Drive folder 004-technician_tool/v0.3.
2026-09-26 17:14:37 +02:00